Masuyama Shinji
Evaluation of a small pulse tube cryocooler by pressure waves
        大島商船高等専門学校紀要 Volume 43
        Page 41-45
        
    published_at 2010-12
            Title
        
        圧力波形による小型パルスチューブ冷凍機の評価
        Evaluation of a small pulse tube cryocooler by pressure waves
        
    
        
            Source Identifiers
        
    
    
            Creator Keywords
        
            Pulse tube cryocooler
            Phase shifter
    This paper describes the experimental results of a small size pulse tube cryocooler (PTC) with three types of phase shifters. The phase shifter plays a key role in the cooling performance of the PTCs. The basic, orifice and double inlet phase shifters have been tested. In particular, we take notice of temperature at the cold end, and pressure at the hot-end of regenerator and pulse tube. The inner diameter and length of pulse tube are 14 mm∅ and 22 cm, respectively. Copper screens (200 mesh) of diameter of 18 mm were filled in the regenerator as a regenerator material. The PTC is operated at 4.5 Hz with an air cooled compressor of 800 W. Attained temperature at the cold end of basic, orifice and double inlet phase shifters were 205.6, 133.7 and 84.5 K, respectively. The characteristics pressure wave curves were observed in each phase shifter.
        
        
            Languages
        
            jpn
    
    
        
            Resource Type
        
        departmental bulletin paper
    
    
        
            Publishers
        
            大島商船高等専門学校
    
    
        
            Date Issued
        
        2010-12
    
    
        
            File Version
        
        Version of Record
    
    
        
            Access Rights
        
        open access
    
    
            Relations
        
            
                
                
                [ISSN]0387-9232
            
            
                
                
                [NCID]AN00031668
            
    