コンテンツメニュー

Cooling performance of a GM cryocooler altering 2nd-stage regenerator materials

大島商船高等専門学校紀要 Volume 42 Page 43-47
published_at 2009-12
OS10042000007.pdf
[fulltext] 845 KB
Title
GM冷凍機の2段目蓄冷材による冷凍性能評価
Cooling performance of a GM cryocooler altering 2nd-stage regenerator materials
Creators Imazu Takuya
Creators Masuyama shinji
Source Identifiers
Creator Keywords
GM cryocooler Gd2O2S regenerator material
The purpose of this study is to improve the cooling capacity of a two-stage Gifford-McMahon (GM) cryocooler at 4.2 K. We focus on regenerator materials of 2nd-stage regenerator. One of the demanded factors for regenerator materials is a high specific heat at the using temperatures. From the point of view, ceramic material, Gd2O2S (GOS), has very attractive property around 4 K. However, effective temperature range of the specific heat of the GOS is narrow. Therefore, we adopted layered structure to the 2nd-stage regenerator. From the experimental results, the cooling power at 4.2 K achieves 0.21 W using the GOS regenerator material. That volumetric ratios of 2nd-stage regenerator are Pb:HoCu2:GOS = 40:30:20. When filling the regenerator materials of Pb and HoCu2 (the volumetric ratios are Pb:HoCu2 = 40:60), the cooling power at 4.2 K is 0.15 W. The results show that the cooling power is 40 % improved using the GOS material.
Languages jpn
Resource Type departmental bulletin paper
Publishers 大島商船高等専門学校
Date Issued 2009-12
File Version Version of Record
Access Rights open access
Relations
[ISSN]0387-9232
[NCID]AN00031668